Yes, It is running ok but its only have the serial flow. I want to
deploy a descriptor which is having the serial flow preeceded by the
parallel flow as I mentioned in the previous mail. If I run using remote
analysis engine it is not working.
On 07/18/2013 06:43 PM, Eddie Epstein wrote:
> On Thu, Jul 18, 2013 at 12:22 AM, reshu.agarwal <reshu.agarwal@orkash.com>wrote:
>
>> On 07/17/2013 07:30 PM, Eddie Epstein wrote:
>>
>>> Component Descriptor Editor
>>>
>> Hi,
>>
>> It is not a flow controller its an aggregate descriptor which is using the
>> flow controller I just put it into flow controller folder for just the
>> testing. If I can not use aggregate descriptor which is useing the flow
>> controller then tell me. The descriptor is given below for your reference:
>>
>>
> Ooops, I misread the top level name as that of the advanced flow controller
> itself.
>
> Have you gotten the uima-as sample applications running OK, in particular
> the Deploy_MeetingDetectorTAE_RemoteRoomNumber.xml sample?
>
> Eddie
>
--
Thanks and Regards,
Reshu Agarwal
|