Subject [jira] [Updated] (MINIFICPP-984) LogAttribute should return to prior behavior or detect text and print it out
Date Fri, 19 Jul 2019 19:09:00 GMT

     [ https://issues.apache.org/jira/browse/MINIFICPP-984?page=com.atlassian.jira.plugin.system.issuetabpanels:all-tabpanel
]

Mr TheSegfault updated MINIFICPP-984:
-------------------------------------
    Description: 
Noticed by user: change in behavior on log attribute payload log.

Prior behavior on text files printed text. In some cases this may have issues.  I think we
took a step forward. We should provide prior behavior and an option to print as hex or return
to prior behavior noticing bugs that caused us to go down this road. Further we should increase
the line length to 200, which is the typical log level length seen in NiFi I believe. Understandably
lines can grow large but 80 is too short.

  was:
Noticed by user: change in behavior on log attribute payload log.

Prior behavior on text files printed text. In some cases this may have issues so  I think
we took a step forward. We should provide prior behavior and an option to print as hex or
return to prior behavior noticing bugs that caused us to go down this road. Further we should
increase the line length to 200, which is the typical log level length seen in NiFi I believe.
Understandably lines can grow large but 80 is too short.


> LogAttribute should return to prior behavior or detect text and print it out
> ----------------------------------------------------------------------------
>
>                 Key: MINIFICPP-984
>                 URL: https://issues.apache.org/jira/browse/MINIFICPP-984
>             Project: Apache NiFi MiNiFi C++
>          Issue Type: Bug
>            Reporter: Mr TheSegfault
>            Assignee: Daniel Bakai
>            Priority: Blocker
>
> Noticed by user: change in behavior on log attribute payload log.
> Prior behavior on text files printed text. In some cases this may have issues.  I think
we took a step forward. We should provide prior behavior and an option to print as hex or
return to prior behavior noticing bugs that caused us to go down this road. Further we should
increase the line length to 200, which is the typical log level length seen in NiFi I believe.
Understandably lines can grow large but 80 is too short.



--