mina-users mailing list archives

Site index · List index
Message view « Date » · « Thread »
Top « Date » · « Thread »
From Ashish <paliwalash...@gmail.com>
Subject Re: Strange bug in CumulativeProtocolDecoder
Date Tue, 07 Feb 2012 10:36:32 GMT
Need to return true when the decoding is done. something like this

if(in.prefixedDataAvaliable(4)) // read message type
 {
    if(in.prefixedDataAvaliable(4)) // read message length
    {
          if(in.remaining() >= messageLength)
          {
               // decode
                   return true;
          }
          else
          {
                return false;
          }
    }

Can you please check this. More details at
http://mina.apache.org/tutorial-on-protocolcodecfilter-for-mina-2x.html

>> Hi. Im using MINA 2.0.4 on windows 7 32-bit. As a decoder im using CPD,
>> running  locally.
>> On client side decoder works without issues, it takes care of incomplete
>> message and more than one message in buffer as well. Nothing is blocking.
>> On server side im using same algorithm.
>>
>> if(in.prefixedDataAvaliable(4)) // read message type
>> {
>>    if(in.prefixedDataAvaliable(4)) // read message length
>>    {
>>          if(in.remaining() >= messageLength)
>>          {
>>               // decode
>>          }
>>          else
>>          {
>>                return false;
>>          }
>>    }
>>    else
>>    {
>>         return false;
>>    }
>> }
>> else
>> {
>>   return false;
>> }
>>
>> Problem is that some of the messages cant pass first step, it doesnt matter
>> if they are incomplet or overcomplet. They return false. But when i
>> manually trying to get int, value which should be read is correct. Why is
>> that happens ? Why it happens only for coupe of messages ?
>> Encoder sends bytes properly.
>>



-- 
thanks
ashish

Blog: http://www.ashishpaliwal.com/blog
My Photo Galleries: http://www.pbase.com/ashishpaliwal

Mime