lucene-dev mailing list archives

Site index · List index
Message view « Date » · « Thread »
Top « Date » · « Thread »
From "Mark Miller (JIRA)" <j...@apache.org>
Subject [jira] Commented: (LUCENE-1209) If setConfig(Config config) is called in resetInputs(), you can turn term vectors off and on by round
Date Sat, 08 Mar 2008 22:57:48 GMT

    [ https://issues.apache.org/jira/browse/LUCENE-1209?page=com.atlassian.jira.plugin.system.issuetabpanels:comment-tabpanel&focusedCommentId=12576644#action_12576644
] 

Mark Miller commented on LUCENE-1209:
-------------------------------------

It seems to me that its not working right. Everything that is set in public void setConfig(Config
config) is only set once for me, not per round. That is unless I apply the above patch. This
means that I cannot seem to set tokenizing, storing, or termvectors per round.

>From what I can tell it is because setConfig is only called once, and so only the first
value is every read for those properties. The patch above puts set config in the resetInputs
method which does get called per round. Not sure if that is the best fix, but I know cannot
currently set those per round and have anything but the first setting take effect.

- Mark

> If setConfig(Config config) is called in resetInputs(), you can turn term vectors off
and on by round
> -----------------------------------------------------------------------------------------------------
>
>                 Key: LUCENE-1209
>                 URL: https://issues.apache.org/jira/browse/LUCENE-1209
>             Project: Lucene - Java
>          Issue Type: Improvement
>          Components: contrib/benchmark
>    Affects Versions: 2.4
>            Reporter: Mark Miller
>            Priority: Trivial
>         Attachments: reset_config.patch
>
>
> I want to be able to run one benchmark that tests things using term vectors and not using
term vectors.
> Currently this is not easy because you cannot specify term vectors per round.
> While you do have to create a new index per round, this automation is preferable to me
in comparison to running two separate tests.
> If it doesn't affect anything else, it would be great to have setConfig(Config config)
called in BasicDocMaker.resetInputs(). This would keep the term vector options up to date
per round if you reset.
> - Mark

-- 
This message is automatically generated by JIRA.
-