jmeter-user mailing list archives

Site index · List index
Message view « Date » · « Thread »
Top « Date » · « Thread »
From Shay Ginsbourg <sginsbo...@gmail.com>
Subject Re: OS process sampler
Date Mon, 23 Jul 2012 14:21:40 GMT
Thanks!



On Mon, Jul 23, 2012 at 2:16 PM, Flavio Cysne <flaviocysne@gmail.com> wrote:
> Did you try adding an & at the end of your command?
>
> If only the & doesn't work try appending this: >/dev/null 2>&1 &
>
> Hope it helps you.
> Flávio Cysne
>
> 2012/7/23 Shay Ginsbourg <sginsbourg@gmail.com>
>
>> Hi,
>>
>> While working with the OS process sampler, the control never returns to
>> Jmeter -
>>
>> For example, if the OS process sampler is used for launching GEDIT on
>> LINUX,
>> then Jmeter is stuck until manually closing GEDIT,
>> and only after that the control returns to Jmeter for executing the
>> following sampler.
>>
>> How can this sampler launch an OS process in a detached manner,
>> so that the control returns to Jmeter before the launched process is
>> manually killed ?
>>
>> Please advise.
>>
>> thanks,
>> Shay
>>
>> ---------------------------------------------------------------------
>> To unsubscribe, e-mail: user-unsubscribe@jmeter.apache.org
>> For additional commands, e-mail: user-help@jmeter.apache.org
>>
>>



-- 
Regards,


Shay Ginsbourg

Regulatory & Testing Affairs Consultant


WWW.GINSBOURG.COM


Providing Regulatory, Medical & Performance Testing services since 2008:


* IEC 62304 Medical Device Software Life Cycle

* IEEE 829 Software Test Documentation

* ISO 14971 Medical Device Risk Management

* FDA 21 CFR Part 11 Software Validation

* IEC 60601-1:2005 3rd ED PEMS - Medical Electrical Equipment

* End-to-end verification, validation, and testing (VV&T)

* FDA and CE submissions

* Open source free testing tools implementation

* Functionality and regression testing

* Software Performance & Load testing

* Software Testing Advanced Automation

* Medical Software Verification & Validation

* Medical Device Verification & Validation

* Medical Device Regulatory Submission

* Organizational Regulatory Qualification


Formerly QA Manager of LoadRunner at Mercury Interactive


M.Sc. cum laude in Bio-Medical Engineering

M.Sc. in Mechanical Engineering


Work:   +972(0)3-5185873

Mobile:  +972(0)54-6690915


Email: sginsbourg@gmail.com


Visit my personal page on LinkedIn at: http://www.linkedin.com/in/shayginsbourg


Please consider your environmental responsibility before printing this e-mail.

---------------------------------------------------------------------
To unsubscribe, e-mail: user-unsubscribe@jmeter.apache.org
For additional commands, e-mail: user-help@jmeter.apache.org


Mime
View raw message