jmeter-user mailing list archives

Site index · List index
Message view « Date » · « Thread »
Top « Date » · « Thread »
From Michael Stover <mstov...@apache.org>
Subject RE: Setting user variables from functions
Date Fri, 24 Sep 2004 13:41:53 GMT
If you make the values in the User Parameters ${_StringFromFile()} then
you can use simple files of one value-per-line to "load" the values from
file.  If you use CSVRead, then you can use csv files to load values
from file.

-Mike

On Fri, 2004-09-24 at 09:37, Ashley Hayes wrote:
> Thanks Sebb,
> 	Must of missed that restriction on User Defined Variables,
> information overload!
> 
> As for the Pre-processor User Parameters, I can't face manually adding the
> 100s/1000s of the users that my tests should use in execution period. I read
> an archived mail where I think someone auto generated an xml file in format
> of the User Parameters and then pasted the contents in to the jmeter test
> plan file. Is this code available anywhere?
> This maybe be an option for me, however jmeter may not perform well with
> 1000s of "User Parameters" entries, as it seems they are implements as an
> array list. 
> 
> It would be nice if there User Parameters could be loaded from a separate
> file, say in the format of the deprecated "HTTP User Parameter Modifier"! 
> 
> Thanks
> A
> 
> 
> -----Original Message-----
> From: sebb [mailto:sebbaz@gmail.com] 
> Sent: 24 September 2004 13:58
> To: JMeter Users List
> Subject: Re: Setting user variables from functions
> 
> 
> Try the Pre-processor User Parameters:
> 
> http://jakarta.apache.org/jmeter/usermanual/component_reference.html#User_Pa
> rameters
> 
> No need to set up multiple users.
> 
> ==
> 
> The Config Element User Defined Variables is described at:
> 
> http://jakarta.apache.org/jmeter/usermanual/component_reference.html#User_De
> fined_Variables
> 
> "Note that the variable's values have to be static: you can't currently use
> other variables in their definition."
> 
> A bit confusing, but that's the way it is ...
> 
> On Fri, 24 Sep 2004 10:36:08 +0100, Ashley Hayes <ashley.hayes@macalla.com>
> wrote:
> > Hi all,
> >         I've created a test plan that has variables defined for my 
> > userid, password, etc.. I would like to populate these variables from 
> > a CSV  file. I tried to achieve this by putting 
> > "${__CSVRead(users.csv,0)}" into the value of the "user defined 
> > variable" that is parent to all my sampler elements. This is obviously 
> > wrong as the value passed in as the userid is the literal 
> > "${__CSVRead(users.csv,0)}", :-(
> > 
> > Is there a pre-processor that I can use to set the value of these 
> > variables for all subsequent sampler executions for that thread? HTTP 
> > User Parameter modifier will not work as I can't guarantee that the 
> > HTTP parameter taking the userid is named the same in every request.
> > 
> > Thanks for you time,
> > Ashley
> > 
> > P.s. I'm new to jmeter and have made the effort to read the user guide 
> > and search the mail archive.
> > 
> > ---------------------------------------------------------------------
> > To unsubscribe, e-mail: jmeter-user-unsubscribe@jakarta.apache.org
> > For additional commands, e-mail: jmeter-user-help@jakarta.apache.org
> > 
> >
> 
> ---------------------------------------------------------------------
> To unsubscribe, e-mail: jmeter-user-unsubscribe@jakarta.apache.org
> For additional commands, e-mail: jmeter-user-help@jakarta.apache.org
> 
> ---------------------------------------------------------------------
> To unsubscribe, e-mail: jmeter-user-unsubscribe@jakarta.apache.org
> For additional commands, e-mail: jmeter-user-help@jakarta.apache.org
-- 
Michael Stover <mstover1@apache.org>
Apache Software Foundation


---------------------------------------------------------------------
To unsubscribe, e-mail: jmeter-user-unsubscribe@jakarta.apache.org
For additional commands, e-mail: jmeter-user-help@jakarta.apache.org


Mime