From "Chris Lambertus (JIRA)" <j...@apache.org>
Subject [jira] [Commented] (INFRA-14113) disk predictive fail on metis bay 6
Date Sun, 31 Dec 2017 21:07:00 GMT

    [ https://issues.apache.org/jira/browse/INFRA-14113?page=com.atlassian.jira.plugin.system.issuetabpanels:comment-tabpanel&focusedCommentId=16307296#comment-16307296
] 

Chris Lambertus commented on INFRA-14113:
-----------------------------------------

Two spare drives have now been added via the CLI tools. Should PD6 fail, the spare should
be swapped in. I will be running a zpool scrub prior to manually removing PD6 from the array
to force a rebuild.

For future reference the secret sauce to adding a drive via the CLI is:

mfiutil show drives
(find the unconfigured new drives)

mfiutil drive clear E1:S8 start
(wait 5-10 seconds)

mfiutil drive clear E1:S8 stop
(clears any bogus config)

mfiutil create jbod -v E1:S8
(creates the drive and dev entries)

zpool add x1 spare mfid8


> disk predictive fail on metis bay 6
> -----------------------------------
>
>                 Key: INFRA-14113
>                 URL: https://issues.apache.org/jira/browse/INFRA-14113
>             Project: Infrastructure
>          Issue Type: Project
>          Components: Hardware
>            Reporter: Chris Lambertus
>            Assignee: Chris Lambertus
>
> Justin @ OSU reports disk predictive fail on metis bay 6



--