Matthieu Morel commented on S4-68:
----------------------------------

As a result, setting the context classloader in streams as resolved in S4-61 will probably
not be needed anymore.
                
> PE Prototypes are created from a Thread with the wrong ClassLoader
> ------------------------------------------------------------------
>
>                 Key: S4-68
>                 URL: https://issues.apache.org/jira/browse/S4-68
>             Project: Apache S4
>          Issue Type: Bug
>    Affects Versions: 0.5
>            Reporter: Daniel Gómez Ferro
>             Fix For: 0.5
>
>
> PE Prototypes are created from a Thread with the wrong ClassLoader. They are created
during the App initialization, which is called by the Deployment Manager from a ZK callback.
> We should rework how the Application initialization is done, possibly submitting the
initialization task to a separate ExecutionService from the ZK callback, and then setting
the right ClassLoader as the Thread contextClassLoader.

--