Subject [Bug 119477] [From Symphony]PPT Export: Diagram bullet can not be displayed correctly after saved as *.ppt in AOO
Date Fri, 14 Sep 2012 02:12:37 GMT
https://issues.apache.org/ooo/show_bug.cgi?id=119477

--- Comment #9 from sunying <sunying@apache.org> ---
solution:
set SvxNumberFormat's startwith value at function ImplGetExtNumberFormat() in
file /impr/svx/source/svdraw/svdfppt.cxx.
It is unnecessary to set rOutliner's StartValue in line 2517 in file
/impr/svx/source/svdraw/svdfppt.cxx.

The patch in file /main/editeng/source/outliner/outliner.cxx is in order to fix
the following defect:
steps:
1.Open AOO, and create a presention,
2.add three line text, 
3.set the text's bullet is numbering.
4.choose the 2rd line, and reset Start at is 4, find the 2rd line's numbering
become 5,refer the attachment "defect screenshot.png".

-- 