That's a good analysis, and what we usually go through when we decide on 
an attribute or a skin property.
I personally don't think we'd need it at the specific level, which I've 
been calling 'per instance'. I think global to the processTrain within 
an application/skin is good enough.

- Jeanne



Simon_Lessard@DMR.CA wrote:

>Hello,
>
>I could do that as well since it would indeed be a nice enhancement, 
>However, I don't know what would be best between a skin property and a tag 
>attribute. Pro of skin property is that since the skin knows what kind of 
>images it use, it would be the best placed to know how many station can be 
>safely rendered. However, skin property is global and will prevent any 
>overload at specific level. Maybe we could have both, a 
>-default-visible-number-stations and a tag atttribute, the tag attribute, 
>if present would be the one used?
>
>
>Regards,
>
>Simon Lessard
>Fujitsu Consulting
>----- Forwarded by Simon Lessard/NOTES on 2006-07-06 16:26 -----
>
>
>Jeanne Waldman <jeanne.waldman@oracle.com>
>2006-07-06 16:20
>Please respond to adffaces-user
> 
>        To:     adffaces-user@incubator.apache.org
>        cc: 
>        Subject:        Re: ProcessTrain Number of "Stops" before 
>"segmenting" configurable?
>
>
>This could be an enhancement. It would be a good example of using a 
>skinning property.
>
>You could add a skin property, like -ora-number-visible-stations (note, 
>I'll have to follow through on the thread regarding changing the -ora- 
>to something else).
>So in the skin file you'd do this:
>af|processTrain {-ora-number-visible-stations: 10 }
>(The default would be 6)
>
>Then we'd need to change the train renderer to honor this number instead 
>of hard-coding it to 6. Then ALL processTrain components that are 
>defined in the application will use this property value defined in the 
>skin.
>
>- Jeanne
>
>Simon_Lessard@DMR.CA wrote:
>
>  
>
>>Hello,
>>
>>Threshold is currently fixed to 6 visible stations and add a 7th that is 
>>the arrow pointing to the next set of steps. This parameter is not 
>>configurable at this time.
>>
>>
>>Sorry,
>>
>>Simon Lessard
>>Fujitsu Consulting
>>
>>
>>    
>>
>
>
>  
>