ignite-user mailing list archives

Site index · List index
Message view « Date » · « Thread »
Top « Date » · « Thread »
From Jonathan mayer <jonrma...@yahoo.com>
Subject Re: BinaryObjectBuilder - setField - Boolean Type - Problem
Date Tue, 08 May 2018 18:37:45 GMT
 Hi Guys,
Thank you both very much for your help.
Yes, a complete reboot did the trick. I had thought that dropping the table would have worked
but now know better.
I am just starting on my journey with Ignite so I imagine I will be on this list quite frequently.
Regards,
Jonathan


    On Tuesday, 8 May 2018, 19:26:47 GMT+10, Ilya Kasnacheev <ilya.kasnacheev@gmail.com>
wrote:  
 
 Hello!

I assume this is because, previously, you managed to write a TEST where F_BOOLEAN was Object.
This is cached so it comes back to haunt you.

The solution here is to remove ignite/work/marshaller/ on all nodes (and all data if it is
persistent) and restart your cluster. Or change type TEST to TEST2 :)

Regards,

-- 
Ilya Kasnacheev

2018-05-08 6:05 GMT+03:00 Jonathan mayer <jonrmayer@yahoo.com>:

Hi there, I am testing different Data Types and have come up against a problem with Boolean.
I have created the following table from within DBeaver:-
CREATE TABLE TEST (   F_ID varchar PRIMARY KEY,   F_INT INTEGER,   F_BOOLEAN BOOLEAN)
WITH "CACHE_NAME=TEST, key_type=java.lang.String, value_type=TEST";

I am try to create Data via an IgniteDataStreamer.
snippet:
BinaryObjectBuilder binaryObjectBuilder = ignite.binary().builder("TEST" );

binaryObjectBuilder.setField(" F_BOOLEAN", true);
etc...
BinaryObject bo = binaryObjectBuilder.build();

String/Integer Types are working fine.
Getting the error message :
Wrong value has been set [typeName=TEST, fieldName=F_BOOLEAN, fieldType=Object, assignedValueType=boolean]

Any help would be appreciated
Jonathan

  
Mime