ignite-user mailing list archives

Site index · List index
Message view « Date » · « Thread »
Top « Date » · « Thread »
From Nikolai Tikhonov <ntikho...@apache.org>
Subject Re: Error while running query against Ignite Server Node
Date Mon, 13 Mar 2017 16:04:26 GMT
Hi!

This exception means that in during data streaming, topology was changed.
It doesn't relate with SQL queries and this exception just logged and does
not break anything.



On Sat, Mar 4, 2017 at 4:23 PM, rishi007bansod <rishi007bansod@gmail.com>
wrote:

> Hi,
>     I am getting following error after running query against Ignite cache
> from Client node,
>
>
> [17:53:28] (err) Failed to execute compound future reducer:
> GridCompoundFuture [rdc=null, initFlag=1, lsnrCalls=0, done=false,
> cancelled=false, err=null, futs=[true]]class
> org.apache.ignite.IgniteCheckedException: DataStreamer request failed
> [node=0a0580b8-2eb1-4531-98d4-b04bb910f0df]
>         at
> org.apache.ignite.internal.processors.datastreamer.
> DataStreamerImpl$Buffer.onResponse(DataStreamerImpl.java:1777)
>         at
> org.apache.ignite.internal.processors.datastreamer.
> DataStreamerImpl$3.onMessage(DataStreamerImpl.java:335)
>         at
> org.apache.ignite.internal.managers.communication.
> GridIoManager.invokeListener(GridIoManager.java:1215)
>         at
> org.apache.ignite.internal.managers.communication.GridIoManager.
> processRegularMessage0(GridIoManager.java:843)
>         at
> org.apache.ignite.internal.managers.communication.
> GridIoManager.access$2100(GridIoManager.java:108)
>         at
> org.apache.ignite.internal.managers.communication.GridIoManager$6.run(
> GridIoManager.java:783)
>         at
> java.util.concurrent.ThreadPoolExecutor.runWorker(
> ThreadPoolExecutor.java:1142)
>         at
> java.util.concurrent.ThreadPoolExecutor$Worker.run(
> ThreadPoolExecutor.java:617)
>         at java.lang.Thread.run(Thread.java:745)
> Caused by: class org.apache.ignite.IgniteCheckedException: DataStreamer
> will
> retry data transfer at stable topology [reqTop=AffinityTopologyVersion
> [topVer=2597, minorTopVer=10], topVer=AffinityTopologyVersion [topVer=2598,
> minorTopVer=0], node=remote]
>         at
> org.apache.ignite.internal.processors.datastreamer.DataStreamProcessor.
> localUpdate(DataStreamProcessor.java:339)
>         at
> org.apache.ignite.internal.processors.datastreamer.DataStreamProcessor.
> processRequest(DataStreamProcessor.java:297)
>         at
> org.apache.ignite.internal.processors.datastreamer.
> DataStreamProcessor.access$000(DataStreamProcessor.java:56)
>         at
> org.apache.ignite.internal.processors.datastreamer.DataStreamProcessor$1.
> onMessage(DataStreamProcessor.java:86)
>         ... 7 more
>
> what is cause for this error?
>
>
>
> --
> View this message in context: http://apache-ignite-users.
> 70518.x6.nabble.com/Error-while-running-query-against-
> Ignite-Server-Node-tp11030.html
> Sent from the Apache Ignite Users mailing list archive at Nabble.com.
>

Mime