Address resolver is needed if there are private and public addresses on the
node and it can be accessed only through the public one. I'm not sure if
that's your case, but it really looks like some ports are still can't be
accessed for some reason. Note that there is not only discovery port (47500
by default), but also communication port (47100 by default). Both of them
should be accessible from the outside on both nodes.