Pavel Tupitsyn updated IGNITE-4856:
-----------------------------------
    Description: 
In certain scenarios .NET {{AppDomain}} can be unloaded and started again. Java part of Ignite
continues to run, but .NET part (including Ignite instances) is lost. User can no longer work
with started nodes, .NET callback pointers are lost, etc.

1) Track AppDomain unload and stop all Ignite instances.
2) When starting Ignite, wait for node with specified name to stop.
3) Make it possible to auto-generate a unique grid name automatically? This may be useful
in app.config.

IIS issues example: http://stackoverflow.com/questions/42961879/how-do-i-retrieve-a-started-ignite-instance-when-a-website-restart-occurs-in-iis/42968183#42968183

  was:
In certain scenarios .NET {{AppDomain}} can be unloaded and started again. Java part of Ignite
continues to run, but .NET part (including Ignite instances) is lost. User can no longer work
with started nodes, .NET callback pointers are lost, etc.

1) Track AppDomain unload and stop all Ignite instances.
2) When starting Ignite, wait for node with specified name to stop.
3) Make it possible to auto-generate a unique grid name automatically?

IIS issues example: http://stackoverflow.com/questions/42961879/how-do-i-retrieve-a-started-ignite-instance-when-a-website-restart-occurs-in-iis/42968183#42968183


> .NET: StopAll on AppDomain unload
> ---------------------------------
>
>                 Key: IGNITE-4856
>                 URL: https://issues.apache.org/jira/browse/IGNITE-4856
>             Project: Ignite
>          Issue Type: Improvement
>          Components: platforms
>    Affects Versions: 1.6
>            Reporter: Pavel Tupitsyn
>              Labels: .NET
>             Fix For: 2.0
>
>
> In certain scenarios .NET {{AppDomain}} can be unloaded and started again. Java part
of Ignite continues to run, but .NET part (including Ignite instances) is lost. User can no
longer work with started nodes, .NET callback pointers are lost, etc.
> 1) Track AppDomain unload and stop all Ignite instances.
> 2) When starting Ignite, wait for node with specified name to stop.
> 3) Make it possible to auto-generate a unique grid name automatically? This may be useful
in app.config.
> IIS issues example: http://stackoverflow.com/questions/42961879/how-do-i-retrieve-a-started-ignite-instance-when-a-website-restart-occurs-in-iis/42968183#42968183



--