ignite-dev mailing list archives

Site index · List index
Message view « Date » · « Thread »
Top « Date » · « Thread »
From "Alexey Goncharuk (JIRA)" <j...@apache.org>
Subject [jira] [Created] (IGNITE-11930) TcpDiscoverySpi does not close bound server socket if discovery thread did not start
Date Mon, 17 Jun 2019 07:32:00 GMT
Alexey Goncharuk created IGNITE-11930:
-----------------------------------------

             Summary: TcpDiscoverySpi does not close bound server socket if discovery thread
did not start
                 Key: IGNITE-11930
                 URL: https://issues.apache.org/jira/browse/IGNITE-11930
             Project: Ignite
          Issue Type: Bug
    Affects Versions: 2.7
            Reporter: Alexey Goncharuk
            Assignee: Alexey Goncharuk
             Fix For: 2.8


See {{ServerImpl.spiStop0(boolean)}}. If the worker did not start, {{U.cancel()}} has no effect
because runner field is not initialized, and server socket is closed in {{onInterrupted()}}
method, which is called from the {{interrupt()}} method on the worker thread.

This results in the server socket not being closed and may lead to tests hang, for example,
in .NET tests.



--