Alexander Belyak created IGNITE-8103:
----------------------------------------

             Summary: Node with BLT is not allowed to join cluster without one
                 Key: IGNITE-8103
                 URL: https://issues.apache.org/jira/browse/IGNITE-8103
             Project: Ignite
          Issue Type: Improvement
          Components: general
    Affects Versions: 2.4
            Reporter: Alexander Belyak


1) Start cluster of 2-3 nodes and activate it, fill some data
2) Stop cluster, clear LFS on first node
3) Start cluster from first node (or start all nodes synchronously)
Expected result: ?
Actual result: "Node with set up BaselineTopology is not allowed to join cluster without one:
cons_srv2"
In the technical point of view it's expected behaviour, because first node with cleared storage
became grid coordinator and reject any connection attempts from nodes with different baseline.
But it's bad for usability: if we always start all nodes together and wanna clear storage
on one node by some reason - we need to define start sequence.



--