> If filter throws exception entry would be passed to listener.

this is strange. Imagine a filter that very rarely throws some runtime
exception due to external or environmental reasons, but in case of normal
execution filter evaluates to false. In case of error entry is passed to a
local listener which can lead to some serious consequences and
inconsistencies in business logic. We probably need to send entry with a
notion that there was an error on server.

--Yakov