If other Timeout Exceptions are specific, shouldn’t this one be specific to
data streamer as well, for consistency reasons, e.g.
IgniteDataStreamerTimeoutExcepiton?

On Tue, Jul 12, 2016 at 2:20 PM, Vladislav Pyatkov <vpyatkov@gridgain.com>
wrote:

> Dmitriy,
>
> I discussed that with Denis and we have decided create new Exception type
> by some reasons:
> 1) The exception need to be unchecked (the behavior means serious problem
> in grid) hence, TimeoutException will implement IgniteException (as
> RintimeException).
>
> 2) Other timeout exception, which follow the logic, are specific (for
> example TransactionTimeoutException).
>
> So TimeoutException will be RuntimeException, will not be specific for
> DataStreamer and can be reuse.
>
> On Tue, Jul 12, 2016 at 1:54 PM, Dmitriy Setrakyan <dsetrakyan@apache.org>
> wrote:
>
> > Thanks Vlad.
> >
> > At a high level, the changes look OK. However, I am not sure about
> > TimeoutException. Don’t we already have other timeout exceptions in
> Ignite?
> > Can we reuse them?
> >
> > D.
> >
> > On Tue, Jul 12, 2016 at 1:51 PM, Vladislav Pyatkov <
> vpyatkov@gridgain.com>
> > wrote:
> >
> > > Dmitriy,
> > >
> > > I have added the description of changes in the JIRA ticket.
> > >
> > > On Tue, Jul 12, 2016 at 1:28 PM, Dmitriy Setrakyan <
> > dsetrakyan@apache.org>
> > > wrote:
> > >
> > > > Hi Vlad,
> > > >
> > > > Can you please list the API changes in the ticket, so others can
> review
> > > > without digging in code?
> > > >
> > > > Thanks,
> > > > D.
> > > >
> > > > On Mon, Jul 11, 2016 at 1:14 PM, Vladislav Pyatkov <
> > > vpyatkov@gridgain.com>
> > > > wrote:
> > > >
> > > > > Igniters,
> > > > >
> > > > > I have implemented timeout in DataStreamer by issue IGNITE-3055
> > > > > <https://issues.apache.org/jira/browse/IGNITE-3055
> > > >(*IgniteDataStreamer
> > > > > can't be timed out*).
> > > > >
> > > > > That lead the change public API:
> > > > >
> > > > > 1) Added set and get methods (IgniteDataStreamer.timeout(long) and
> > > > > IgniteDataStreamer.timeout()) for establish. Default value is -1,
> > means
> > > > > unlimited time.
> > > > >
> > > > > 2) Added new TimeoutException (inherited IgniteException). The
> > > exception
> > > > > will thrown when timeout will be reached (may be take place in
> > > > > IgniteDataStreamer.addData, IgniteDataStreamer.close and
> > > > > IgniteDataStreamer.flash operations).
> > > > >
> > > > > Dmitry, colleagues, please comment or approve.
> > > > >
> > > > >
> > > >
> > >
> >
>