On 11/17/2015 9:37 PM, Yakov Zhdanov wrote:
> 1. Understood
> 2. Well, I understand that object gets deserialized on get from cache and
> this most probably should not cause any issue. However, code does not look
> healthy and someone may think that there is an issue - field is not
> volatile, initialized in constructor, has sync setter, but is accessed
> several times in code outside of sync. Can you please refactor this?
> 3. Yes, Denis is looking into this. And I think your issue will be fixed in
> the scope of Denis one.
I'm afraid that my changes won't fix the issue in Vladislav's 
implementation.
However, when my changes are merged we will be able to rework these 
semaphore failover tests and fix any issue in the semaphore impl related 
to failover. I can take care of this.

--
Denis

>
> Vlad, can you please refactor [2] and I will pick it up and merge tomorrow.
>
> Thank you for your interest and contribution!
>
> --Yakov
>
> 2015-11-17 21:30 GMT+04:00 Vladisav Jelisavcic <vladisavj@gmail.com>:
>
>> Hi Yakov,
>> 1. Yes
>>
>> 2. if you mean that nodeMap is accessed in onNodeRemoved(UUID nodeID)
>> method of the GridCacheSemaphoreImpl class,
>> it shouldn't be a problem, but it can be changed easily not to do so;
>>
>> 3.
>>
>> org.apache.ignite.internal.processors.cache.datastructures.GridCacheAbstractDataStructuresFailoverSelfTest#testSemaphoreConstantTopologyChangeFailoverSafe()
>>
>> org.apache.ignite.internal.processors.cache.datastructures.GridCacheAbstractDataStructuresFailoverSelfTest#testSemaphoreConstantMultipleTopologyChangeFailoverSafe()
>>
>> I think the problem is with the atomicity of the simulated grid failure;
>> once stopGrid() is called for a node, other threads on this same node start
>> throwing interrupted exceptions,
>> which are in turn not handled properly in the
>> GridCacheAbstractDataStructuresFailoverSelfTest;
>> Those exceptions shouldn't be dealt with inside the GridCacheSemaphoreImpl
>> itself.
>> In a realworld node failure scenario, all those threads would fail at the
>> same time
>> (none of them would influence the rest of the grid anymore);
>>
>> I think fixing the issue Denis is working on can fix this (IGNITE-801 and
>> IGNITE-803)
>> Am i right? Does it makes sense?
>>
>>
>> Best regards,
>> Vladisav
>>
>>


Mime