Hi,

How can I remove the properties instead of removing the warnings ?
I tried to comment the properties in "hive-site.xml" but the proprties were
restored after hive restart.

Regards,
Philippe

On Wed, Jan 28, 2015 at 6:06 AM, Navis류승우 <navis.ryu@nexr.com> wrote:

> Those configurations are all deprecated and you can remove warning message
> by setting hive.conf.validation=false.
>
> Don't know why Ambari needs that configurations.
>
> Thanks,
> Navis
>
>
>
> 2015-01-28 12:40 GMT+09:00 Devopam Mittra <devopam@gmail.com>:
>
>> +1
>>
>> I also need help on this one in particular
>>
>> regards
>> Devopam
>>
>> On Tue, Jan 27, 2015 at 7:44 PM, Philippe Kernévez <pkernevez@octo.com>
>> wrote:
>>
>>> Hi,
>>>
>>> I had several warning like " WARN conf.HiveConf: HiveConf of name
>>> hive.optimize.mapjoin.mapreduce does not exist" when I run hive.
>>>
>>> Extract from /etc/hive/conf/hive-site.xml :
>>> "    <property>
>>>       <name>hive.optimize.mapjoin.mapreduce</name>
>>>       <value>true</value>
>>>     </property>""
>>>
>>> I don't find that properties in hive configuration but Amabari does't
>>> allow to remove those parameters and have a documentation for them. Should
>>> I remove them ?
>>>
>>> The full list is :
>>> WARN conf.HiveConf: HiveConf of name hive.optimize.mapjoin.mapreduce
>>> does not exist
>>> WARN conf.HiveConf: HiveConf of name hive.heapsize does not exist
>>> WARN conf.HiveConf: HiveConf of name hive.server2.enable.impersonation
>>> does not exist
>>> WARN conf.HiveConf: HiveConf of name hive.semantic.analyzer.factory.impl
>>> does not exist
>>> WARN conf.HiveConf: HiveConf of name
>>> hive.auto.convert.sortmerge.join.noconditionaltask does not exist
>>>
>>> Regards,
>>> Philippe Kernévez
>>>
>>>
>>
>>
>> --
>> Devopam Mittra
>> Life and Relations are not binary
>>
>
>


-- 