hbase-dev mailing list archives

Site index · List index
Message view « Date » · « Thread »
Top « Date » · « Thread »
From Lars George <lars.geo...@gmail.com>
Subject Re: Config Option Obsolete
Date Thu, 02 Jun 2011 06:44:45 GMT
Thanks Stack! My thoughts exactly.

On Wed, Jun 1, 2011 at 7:35 PM, Stack <stack@duboce.net> wrote:
> On Wed, Jun 1, 2011 at 7:21 AM, Lars George <lars.george@gmail.com> wrote:
>> Hi,
>>
>> hbase.regionserver.thread.splitcompactcheckfrequency
>>
>> Seems to be obsolete now that the flush is event triggered,
>
> I removed it.
>
>
>> implicitly triggers the above check. Also this
>>
>>  <property>
>>    <name>hbase.server.thread.wakefrequency</name>
>>    <value>10000</value>
>>    <description>Time to sleep in between searches for work (in milliseconds).
>>    Used as sleep interval by service threads such as log roller.
>>    </description>
>>  </property>
>>
>> which is used in this scenario to trigger the check when there is no
>> event (put/delete etc.) is quite ambiguous and warrants for a better
>> explanation. No?
>>
>
> Seems like this config. is use all over.  Its used so much its almost
> dangerous to change -- who knows how it'd ripple through the system.
> We should obsolete it and make new individual configs whereever its
> used?  I made an issue.
>
> St.Ack
>

Mime