[classlib][pack200] Init methods cannot be synchronized
-------------------------------------------------------

                 Key: HARMONY-5654
                 URL: https://issues.apache.org/jira/browse/HARMONY-5654
             Project: Harmony
          Issue Type: Bug
          Components: Classlib
         Environment: All pack200
            Reporter: Andrew Cornwall


In the current code, it's possible for a CPMethod  <init> to be emitted as synchronized.
This will not pass Sun's verification. For instance, if you run pack200 on itself, NewAttributeBands$LayoutElement
in the following will be emitted with a synchronized <init>.

I've temporarily hacked this with the following code in CPMethod:

	public CPMethod(CPUTF8 name, CPUTF8 descriptor, long flags, List attributes) {
		// TODO Check that we only pass these on, or remap
        super(name, descriptor, 0x7FFF & flags, attributes);
	    if(name.underlyingString().equals("<init>")) {
	        // hack hack - init should never be synchronized
	        SegmentUtils.debug("Hacking off synchronized on an init method");
	        this.flags = (short)(this.flags & 0x7FDF);
	    }
	}

but I really need to look into it more deeply and find out why the 0x20 flag is being passed