Timo Walther commented on FLINK-24054:
--------------------------------------

It really depends on the use case. For our current Kafka sink implementation, this might not
be an issue. But strictly speaking the current behavior is incorrect. +I and +U might trigger
different downstream logic. [See this example|https://github.com/apache/flink/blob/master/flink-table/flink-table-planner/src/test/java/org/apache/flink/table/planner/runtime/stream/sql/DataStreamJavaITCase.java#L643]
I had to modify the materialization logic because +U requires a look up by primary key, whereas
+I should simply be forwarded.

> Let SinkUpsertMaterializer emit +U instead of only +I
> -----------------------------------------------------
>
>                 Key: FLINK-24054
>                 URL: https://issues.apache.org/jira/browse/FLINK-24054
>             Project: Flink
>          Issue Type: Bug
>          Components: Table SQL / Runtime
>            Reporter: Timo Walther
>            Assignee: Timo Walther
>            Priority: Blocker
>             Fix For: 1.14.0
>
>
> Currently, {{SinkUpsertMaterializer}} is not able to emit +U's but will always emit +I's.
Thus, resulting changelogs are incorrect strictly speaking and only valid when treating +U
and +I as similar changes in downstream operators.



--