From StephanEwen <...@git.apache.org>
Subject [GitHub] flink pull request: [streaming] [wip] Fault tolerance prototype (f...
Date Sun, 08 Mar 2015 22:24:20 GMT
Github user StephanEwen commented on a diff in the pull request:

    --- Diff: flink-runtime/src/main/java/org/apache/flink/runtime/executiongraph/ExecutionGraph.java
    @@ -471,6 +508,7 @@ void jobVertexInFinalState(ExecutionJobVertex ev) {
     						if (current == JobStatus.FAILING) {
     							if (numberOfRetriesLeft > 0 && transitionState(current, JobStatus.RESTARTING))
    +								restart();
    --- End diff --
    This seems wrong here. The restart() call must be asynchronous and should respect the

If your project is set up for it, you can reply to this email and have your