flink-dev mailing list archives

Site index · List index
Message view « Date » · « Thread »
Top « Date » · « Thread »
From "Joseph Sims (JIRA)" <j...@apache.org>
Subject [jira] [Created] (FLINK-4741) WebRuntimeMonitor does not shut down all of it's threads (EventLoopGroups) on exit.
Date Tue, 04 Oct 2016 22:06:20 GMT
Joseph Sims created FLINK-4741:
----------------------------------

             Summary: WebRuntimeMonitor does not shut down all of it's threads (EventLoopGroups)
on exit.
                 Key: FLINK-4741
                 URL: https://issues.apache.org/jira/browse/FLINK-4741
             Project: Flink
          Issue Type: Bug
          Components: Core
    Affects Versions: 1.1.2
            Reporter: Joseph Sims


WebRuntimeMonitor does not shutdown correctly, causing the overall application to hang on
shutdown. It shuts down bootstrap.group (EventLoopGroup) but not the bootstrap.childGroup
(EventLoopGroup).
If WebRuntimeMonitor is not used (local.start-webserver=false), this problem does not occur.

Class: WebRuntimeMonitor
method: stop()
Line: ~387

Called:
    bootstrap.group().shutdownGracefully()
Not called:
    bootstrap.childGroup().shutdownGracefully()





--
This message was sent by Atlassian JIRA
(v6.3.4#6332)

Mime
View raw message