From "Richard S. Hall (JIRA)" <j...@apache.org>
Subject [jira] Resolved: (FELIX-895) File Install treats configuration files with identical subnames as the same configuration
Date Wed, 11 Mar 2009 16:12:50 GMT

     [ https://issues.apache.org/jira/browse/FELIX-895?page=com.atlassian.jira.plugin.system.issuetabpanels:all-tabpanel

Richard S. Hall resolved FELIX-895.

       Resolution: Fixed
    Fix Version/s: fileinstall-0.9.2

Peter reviewed the patch and I just applied it. I made some formatting changes as well as
fixed some discrepancies with the use of 'ConfigurationEntry' and 'ConfigurationKey' in the
comments and variable names. I deployed a snapshot.

Paul, please verify if the snapshot resolves the issue for you. If so, please close this
bug. Thanks.

Thanks to Filippo for the patch.

> File Install treats configuration files with identical subnames as the same configuration
> -----------------------------------------------------------------------------------------
>                 Key: FELIX-895
>                 URL: https://issues.apache.org/jira/browse/FELIX-895
>             Project: Felix
>          Issue Type: Bug
>          Components: File Install
>         Environment: NA
>            Reporter: Paul Neyens
>            Assignee: Peter Kriens
>             Fix For: fileinstall-0.9.2
>         Attachments: FELIX-895.patch
> Suppose you have two ManagedServiceFactory instances registered with pids 'com.acme.abc'
and 'com.acme.xyz'
> To configure a default instance for each of the factories I created two .cfg files to
be handled by File Install: com.acme.xyz-default.cfg and com.acme.abc-default.cfg
> What seems to happen is that File Install creates a first configuration (correctly) and
then updates that configuration to the contents of the second configuration file. Apparently
because the subname is the same. (filename ::= <pid> ( '-' <subname> )? '.cfg')
> Possible fix: File Install (class DirectoryWatcher) uses property _alias_factory_pid
to identify and retrieve the configurations it manages. The value for this property is currently
set to <subname>. A possible fix could be to use <pid>-<subname> (or even
<filename>) as identification value.

This message is automatically generated by JIRA.
You can reply to this email to add a comment to the issue online.

View raw message