Subject [jira] [Commented] (DRILL-5097) Using store.parquet.reader.int96_as_timestamp gives IOOB whereas convert_from works
Date Mon, 16 Jan 2017 13:10:26 GMT

    [ https://issues.apache.org/jira/browse/DRILL-5097?page=com.atlassian.jira.plugin.system.issuetabpanels:comment-tabpanel&focusedCommentId=15823941#comment-15823941
] 

ASF GitHub Bot commented on DRILL-5097:
---------------------------------------

Github user vdiravka commented on a diff in the pull request:

    https://github.com/apache/drill/pull/697#discussion_r96212464
  
    --- Diff: exec/java-exec/src/main/java/org/apache/drill/exec/store/parquet/columnreaders/NullableFixedByteAlignedReaders.java
---
    @@ -110,9 +110,14 @@ protected void readField(long recordsToReadInThisPass) {
     
       /**
        * Class for reading parquet fixed binary type INT96, which is used for storing hive,
    -   * impala timestamp values with nanoseconds precision. So it reads such values as a
drill timestamp.
    +   * impala timestamp values with nanoseconds precision (12 bytes). So it reads such
values as a drill timestamp (8 bytes).
        */
       static class NullableFixedBinaryAsTimeStampReader extends NullableFixedByteAlignedReader<NullableTimeStampVector>
{
    +    /**
    +     * The width of each element of the TimeStampVector is 8 byte(s).
    +     */
    +    private static final int timestampLengthInBits = 64;
    --- End diff --
    
    Agree. Done.


> Using store.parquet.reader.int96_as_timestamp gives IOOB whereas convert_from works
> -----------------------------------------------------------------------------------
>
>                 Key: DRILL-5097
>                 URL: https://issues.apache.org/jira/browse/DRILL-5097
>             Project: Apache Drill
>          Issue Type: Bug
>          Components: Execution - Data Types, Storage - Parquet
>    Affects Versions: 1.9.0
>            Reporter: Vitalii Diravka
>            Assignee: Vitalii Diravka
>             Fix For: Future
>
>         Attachments: data.snappy.parquet
>
>
> Using store.parquet.reader.int96_as_timestamp gives IOOB whereas convert_from works.

> The below query succeeds:
> {code}
> select c, convert_from(d, 'TIMESTAMP_IMPALA') from dfs.`/drill/testdata/parquet_timestamp/spark_generated/d3`;
> {code}
> The below query fails:
> {code}
> 0: jdbc:drill:zk=10.10.100.190:5181> alter session set `store.parquet.reader.int96_as_timestamp`
= true;
> +-------+---------------------------------------------------+
> |  ok   |                      summary                      |
> +-------+---------------------------------------------------+
> | true  | store.parquet.reader.int96_as_timestamp updated.  |
> +-------+---------------------------------------------------+
> 1 row selected (0.231 seconds)
> 0: jdbc:drill:zk=10.10.100.190:5181> select c, d from dfs.`/drill/testdata/parquet_timestamp/spark_generated/d3`;
> Error: SYSTEM ERROR: IndexOutOfBoundsException: readerIndex: 0, writerIndex: 131076 (expected:
0 <= readerIndex <= writerIndex <= capacity(131072))
> Fragment 0:0
> [Error Id: bd94f477-7c01-420f-8920-06263212177b on qa-node190.qa.lab:31010] (state=,code=0)
> {code}



--