db-derby-dev mailing list archives

Site index · List index
Message view « Date » · « Thread »
Top « Date » · « Thread »
From "Kathey Marsden (JIRA)" <j...@apache.org>
Subject [jira] Commented: (DERBY-4786) Shutdown command without username and password should work with mixed client and network server releases.
Date Thu, 09 Sep 2010 15:49:33 GMT

    [ https://issues.apache.org/jira/browse/DERBY-4786?page=com.atlassian.jira.plugin.system.issuetabpanels:comment-tabpanel&focusedCommentId=12907662#action_12907662

Kathey Marsden commented on DERBY-4786:

Hi Mamta, I will look at the patch today but to answer your question, I think the  behavior
 you have  is fine with existing old versions but we should backport the recognition of level
2 protocol to the early branches so users running on the latest version on the branch, won't
see the error.  I think we should be careful to document that moving forward, instead of changing
existing commands, new API's  should create a new COMMAND_XXX command instead of bumping the
protocol version. Maybe a big  code comment around PROTOCOL_VERSION would be a good  place
to put this.

It would be good to have some sort of automated test for this. The comments in DERBY-3644
seem to indicate that the compatibility tests exposed the problem.   Are those still run anywhere?

> Shutdown command without username and password should work with mixed client and network
server releases.
> ---------------------------------------------------------------------------------------------------------
>                 Key: DERBY-4786
>                 URL: https://issues.apache.org/jira/browse/DERBY-4786
>             Project: Derby
>          Issue Type: Bug
>          Components: Network Client, Network Server
>    Affects Versions:,,,
>            Reporter: Mamta A. Satoor
>            Assignee: Mamta A. Satoor
>         Attachments: DERBY4786_patch1_diff.txt, DERBY4786_patch2_diff.txt
> DERBY-2109 introduced optional parameters username and password to the shutdown command.
But with this fix, the existing shutdown command which does not use username and password
stopped working from client with DERBY-2109 changes against a network server without DERBY-2109
> This jira is to ensure that existing shutdown command without user name and password
still works fine between different releases of client and network server(with or without DERBY-2109).
The new shutdown command introduced by DERBY-2109 will work obviosuly only on client and server
with DERBY-2109 changes. For client/server not with DERBY-2109 changes attempting to user
use name and password will get an error.