cxf-issues mailing list archives

Site index · List index
Message view « Date » · « Thread »
Top « Date » · « Thread »
From "Akitoshi Yoshida (JIRA)" <j...@apache.org>
Subject [jira] [Resolved] (CXF-6667) Closing a source sequence in WS-RM may lead to inconsistent sequence status
Date Thu, 05 Nov 2015 13:36:27 GMT

     [ https://issues.apache.org/jira/browse/CXF-6667?page=com.atlassian.jira.plugin.system.issuetabpanels:all-tabpanel
]

Akitoshi Yoshida resolved CXF-6667.
-----------------------------------
       Resolution: Fixed
    Fix Version/s: 3.0.8
                   3.1.5

> Closing a source sequence in WS-RM may lead to inconsistent sequence status
> ---------------------------------------------------------------------------
>
>                 Key: CXF-6667
>                 URL: https://issues.apache.org/jira/browse/CXF-6667
>             Project: CXF
>          Issue Type: Bug
>          Components: WS-* Components
>    Affects Versions: 3.0.7, 3.1.4
>            Reporter: Akitoshi Yoshida
>            Assignee: Akitoshi Yoshida
>             Fix For: 3.1.5, 3.0.8
>
>
> This issue affets WS-RM feature used with RMStore.
> When the source sequence is closed by an out-of-band close message (sending CloseSequence
in WS-RM 1.1 or sending an empty LastMessage in WS-RM 1.0), the sequence status in the RMStore
is not updated. As a result, when the endpoint is shutdown and restarted, it will find the
old sequence which was actually closed and use that sequence to send new messages. This may
lead to message loss at the server under WS-RM 1.0 or to a permanent error under WS-RM 1.1.
> More precisely, this issue can happen when the following conditions hold.
> 1. the sequence is closed either upon the shutdown of the WS-RM endpoint (e.g., when
its terminateOnShutdown is set to true) or when the closeSequence operation is invoked by
other means (e.g., over JMX console)
> 2. there is at least one unacknowledged message still stored in the sequence
> 3. a persistent storage is used
> Although the underlining issue itself also existed in CXF 2.7.x, because the default
value of termninateOnShutdown property in CXF 3.0 was changed [1] from false to true, this
issue can be observed when migrating scenarios from CXF 2.7.x to CXF 3.x.x.
> [1]
> https://github.com/apache/cxf/commit/98d04f03af91e51e3e700f6ddb1c5fb91af07495



--
This message was sent by Atlassian JIRA
(v6.3.4#6332)