cxf-issues mailing list archives

Site index · List index
Message view « Date » · « Thread »
Top « Date » · « Thread »
From "Willem Jiang (JIRA)" <j...@apache.org>
Subject [jira] Created: (CXF-3214) CXFBusLifeCycleManager will call the preshutdown twice if when the BusApplicationContext is closed
Date Wed, 22 Dec 2010 08:32:01 GMT
CXFBusLifeCycleManager will call the preshutdown twice if when the BusApplicationContext is
closed
--------------------------------------------------------------------------------------------------

                 Key: CXF-3214
                 URL: https://issues.apache.org/jira/browse/CXF-3214
             Project: CXF
          Issue Type: Bug
          Components: Core
    Affects Versions: 2.3.1, 2.2.12, 2.2.11, 2.3.0, 2.2.10, 2.0.13, 2.1.10
            Reporter: Willem Jiang
            Assignee: Willem Jiang
            Priority: Minor
             Fix For: 2.3.2, 2.2.13, 2.4


When I write the test of BusApplicationListenerTest I found the BusLifeCycleListener will
be called twice when the application context is closed.
The code of CXFBusLifeCycleManager should be changed like this
{code}
--- rt/core/src/main/java/org/apache/cxf/buslifecycle/CXFBusLifeCycleManager.java	(revision
1051771)
+++ rt/core/src/main/java/org/apache/cxf/buslifecycle/CXFBusLifeCycleManager.java	(working
copy)
@@ -78,9 +78,11 @@
     
     public void preShutdown() {
         // TODO inverse order of registration?
-        preShutdownCalled = true;
-        for (BusLifeCycleListener listener : listeners) {
-            listener.preShutdown();
+        if (!preShutdownCalled) { 
+            preShutdownCalled = true;
+            for (BusLifeCycleListener listener : listeners) {
+                listener.preShutdown();
+            }
         }
     }

{code}

-- 
This message is automatically generated by JIRA.
-