Brent N Atkinson commented on CONTINUUM-1200:
---------------------------------------------

This seems to remedy the case issued on the ticket (leading paren), and it works for my case
as well (contains single quote). Closed it is.

> Password Characters Not Supported in SCM Checkout
> -------------------------------------------------
>
>                 Key: CONTINUUM-1200
>                 URL: http://jira.codehaus.org/browse/CONTINUUM-1200
>             Project: Continuum
>          Issue Type: Bug
>          Components: SCM
>    Affects Versions: 1.1-alpha-1
>            Reporter: Stephen Duncan Jr
>            Assignee: Olivier Lamy
>             Fix For: 1.2
>
>
> Certain characters are not supported for the password for an SCM checkout.  For instance
if a ')' is the first character, then the command fails.  This is because the password is
provided as a CLI parameter, and is not surrounded by quotes.  Obviously, adding quotes might
break other passwords, so it would be best to pass the password along some other way.

-- 