From "Sebb (JIRA)" <j...@apache.org>
Subject [jira] Updated: (NET-180) Telnet EOR is "consumed" by TelnetInputStream when in BINARY transmission
Date Sun, 11 Jul 2010 11:30:53 GMT

     [ https://issues.apache.org/jira/browse/NET-180?page=com.atlassian.jira.plugin.system.issuetabpanels:all-tabpanel
]

Sebb updated NET-180:
---------------------

    Component/s: Telnet

> Telnet EOR is "consumed" by TelnetInputStream when in BINARY transmission
> -------------------------------------------------------------------------
>
>                 Key: NET-180
>                 URL: https://issues.apache.org/jira/browse/NET-180
>             Project: Commons Net
>          Issue Type: Bug
>          Components: Telnet
>    Affects Versions: 1.4
>         Environment: Applies to all platforms
>            Reporter: Chris Jones
>
> I have a TN5250 client (see rfc1205) which extends TelnetClient. Basically, the client
negotiates BINARY transmission and operates in block-mode. However the host sends IAC EOR
at the end of each block in order to notify the client that the transmission of the block
of data is complete, and the client should build the display. The problem is that the IAC
EOR is "consumed" by the TelnetInputStream and therefore never reaches the client.
> There are a few ways this could be handled, here are couple of suggestions (the 2nd is
probably better):-
> 1. Within TelnetInputStream, treat IAC EOR as data when in BINARY transmission state
> 2. Extend TelnetNotificationHandler and send notifications of all Telnet Commands received

-- 
This message is automatically generated by JIRA.
-