commons-issues mailing list archives

Site index · List index
Message view « Date » · « Thread »
Top « Date » · « Thread »
From "Sebb (JIRA)" <j...@apache.org>
Subject [jira] Resolved: (NET-328) FromNetASCIIInputStream.read(byte[], int, int) may change length passed to superclass if not doing conversion
Date Sun, 11 Jul 2010 23:18:49 GMT

     [ https://issues.apache.org/jira/browse/NET-328?page=com.atlassian.jira.plugin.system.issuetabpanels:all-tabpanel
]

Sebb resolved NET-328.
----------------------

    Fix Version/s: 2.1
       Resolution: Fixed

Fixed

> FromNetASCIIInputStream.read(byte[], int, int) may change length passed to superclass
if not doing conversion
> -------------------------------------------------------------------------------------------------------------
>
>                 Key: NET-328
>                 URL: https://issues.apache.org/jira/browse/NET-328
>             Project: Commons Net
>          Issue Type: Bug
>    Affects Versions: 2.0
>            Reporter: Sebb
>            Priority: Minor
>             Fix For: 2.1
>
>
> The method FromNetASCIIInputStream.read(byte[], int, int) may change the length passed
to superclass if not doing conversion.
> It should probably check  _noConversionRequired and call the super-class before recalculating
the length.
> That is
> {code}
> if (_noConversionRequired)
>     return super.read(buffer, offset, __length);
> {code}
> should be done at the very start of the method.

-- 
This message is automatically generated by JIRA.
-