cloudstack-dev mailing list archives

Site index · List index
Message view « Date » · « Thread »
Top « Date » · « Thread »
From Wido den Hollander <w...@widodh.nl>
Subject Re: [MERGE] disk_io_throttling to MASTER
Date Sat, 01 Jun 2013 09:32:20 GMT
Hi Wei,

On 06/01/2013 08:24 AM, Wei ZHOU wrote:
> Wido,
>
> Exactly. I have pushed the features into master.
>
> If anyone object thems for technical reason till Monday, I will revert them.

For the sake of clarity I just want to mention again that we should 
change the total IOps to R/W IOps asap so that we never release a 
version with only total IOps.

You laid the groundwork for the I/O throttling and that's great! We 
should however prevent that we create legacy from day #1.

Wido

> -Wei
>
>
> 2013/5/31 Wido den Hollander <wido@widodh.nl>
>
>> On 05/31/2013 03:59 PM, John Burwell wrote:
>>
>>> Wido,
>>>
>>> +1 -- this enhancement must to discretely support read and write IOPS.  I
>>> don't see how it could be fixed later because I don't see how we correctly
>>> split total IOPS into read and write.  Therefore, we would be stuck with a
>>> total unless/until we decided to break backwards compatibility.
>>>
>>>
>> What Wei meant was merging it into master now so that it will go in the
>> 4.2 branch and add Read / Write IOps before the 4.2 release so that 4.2
>> will be released with Read and Write instead of Total IOps.
>>
>> This is to make the May 31st feature freeze date. But if the window moves
>> (see other threads) then it won't be necessary to do that.
>>
>> Wido
>>
>>
>>   I also completely agree that there is no association between network and
>>> disk I/O.
>>>
>>> Thanks,
>>> -John
>>>
>>> On May 31, 2013, at 9:51 AM, Wido den Hollander <wido@widodh.nl> wrote:
>>>
>>>   Hi Wei,
>>>>
>>>> On 05/31/2013 03:13 PM, Wei ZHOU wrote:
>>>>
>>>>> Hi Wido,
>>>>>
>>>>> Thanks. Good question.
>>>>>
>>>>> I  thought about at the beginning. Finally I decided to ignore the
>>>>> difference of read and write mainly because the network throttling did
>>>>> not
>>>>> care the difference of sent and received bytes as well.
>>>>>
>>>>
>>>> That reasoning seems odd. Networking and disk I/O completely different.
>>>>
>>>> Disk I/O is much more expensive in most situations then network bandwith.
>>>>
>>>>   Implementing it will be some copy-paste work. It could be implemented in
>>>>> few days. For the deadline of feature freeze, I will implement it after
>>>>> that , if needed.
>>>>>
>>>>>
>>>> It think it's a feature we can't miss. But if it goes into the 4.2
>>>> window we have to make sure we don't release with only total IOps and fix
>>>> it in 4.3, that will confuse users.
>>>>
>>>> Wido
>>>>
>>>>   -Wei
>>>>>
>>>>>
>>>>>
>>>>>
>>>>> 2013/5/31 Wido den Hollander <wido@widodh.nl>
>>>>>
>>>>>   Hi Wei,
>>>>>>
>>>>>>
>>>>>> On 05/30/2013 06:03 PM, Wei ZHOU wrote:
>>>>>>
>>>>>>   Hi,
>>>>>>> I would like to merge disk_io_throttling branch into master.
>>>>>>> If nobody object, I will merge into master in 48 hours.
>>>>>>> The purpose is :
>>>>>>>
>>>>>>> Virtual machines are running on the same storage device (local
>>>>>>> storage or
>>>>>>> share strage). Because of the rate limitation of device (such
as
>>>>>>> iops), if
>>>>>>> one VM has large disk operation, it may affect the disk performance
of
>>>>>>> other VMs running on the same storage device.
>>>>>>> It is neccesary to set the maximum rate and limit the disk I/O
of VMs.
>>>>>>>
>>>>>>>
>>>>>>>   Looking at the code I see you make no difference between Read
and
>>>>>> Write
>>>>>> IOps.
>>>>>>
>>>>>> Qemu and libvirt support setting both a different rate for Read and
>>>>>> Write
>>>>>> IOps which could benefit a lot of users.
>>>>>>
>>>>>> It's also strange, in the polling side you collect both the Read
and
>>>>>> Write
>>>>>> IOps, but on the throttling side you only go for a global value.
>>>>>>
>>>>>> Write IOps are usually much more expensive then Read IOps, so it
seems
>>>>>> like a valid use-case where that an admin would set a lower value
for
>>>>>> write
>>>>>> IOps vs Read IOps.
>>>>>>
>>>>>> Since this only supports KVM at this point I think it would be of
great
>>>>>> value to at least have the mechanism in place to support both,
>>>>>> implementing
>>>>>> this later would be a lot of work.
>>>>>>
>>>>>> If a hypervisor doesn't support setting different values for read
and
>>>>>> write you can always sum both up and set that as the total limit.
>>>>>>
>>>>>> Can you explain why you implemented it this way?
>>>>>>
>>>>>> Wido
>>>>>>
>>>>>>    The feature includes:
>>>>>>
>>>>>>>
>>>>>>> (1) set the maximum rate of VMs (in disk_offering, and global
>>>>>>> configuration)
>>>>>>> (2) change the maximum rate of VMs
>>>>>>> (3) limit the disk rate (total bps and iops)
>>>>>>> JIRA ticket: https://issues.apache.org/****
>>>>>>> jira/browse/CLOUDSTACK-1192<https://issues.apache.org/**jira/browse/CLOUDSTACK-1192>
>>>>>>> <ht**tps://issues.apache.org/jira/**browse/CLOUDSTACK-1192<https://issues.apache.org/jira/browse/CLOUDSTACK-1192>
>>>>>>>>
>>>>>>> FS (I will update later) :
>>>>>>> https://cwiki.apache.org/****confluence/display/CLOUDSTACK/****<https://cwiki.apache.org/**confluence/display/CLOUDSTACK/**>
>>>>>>> VM+Disk+IO+Throttling<https://**cwiki.apache.org/confluence/**
>>>>>>> display/CLOUDSTACK/VM+Disk+IO+**Throttling<https://cwiki.apache.org/confluence/display/CLOUDSTACK/VM+Disk+IO+Throttling>
>>>>>>>>
>>>>>>> Merge check list :-
>>>>>>>
>>>>>>> * Did you check the branch's RAT execution success?
>>>>>>> Yes
>>>>>>>
>>>>>>> * Are there new dependencies introduced?
>>>>>>> No
>>>>>>>
>>>>>>> * What automated testing (unit and integration) is included in
the new
>>>>>>> feature?
>>>>>>> Unit tests are added.
>>>>>>>
>>>>>>> * What testing has been done to check for potential regressions?
>>>>>>> (1) set the bytes rate and IOPS rate on CloudStack UI.
>>>>>>> (2) VM operations, including
>>>>>>> deploy, stop, start, reboot, destroy, expunge. migrate, restore
>>>>>>> (3) Volume operations, including
>>>>>>> Attach, Detach
>>>>>>>
>>>>>>> To review the code, you can try
>>>>>>> git diff c30057635d04a2396f84c588127d7e****be42e503a7
>>>>>>> f2e5591b710d04cc86815044f5823e****73a4a58944
>>>>>>>
>>>>>>> Best regards,
>>>>>>> Wei
>>>>>>>
>>>>>>> [1]
>>>>>>> https://cwiki.apache.org/****confluence/display/CLOUDSTACK/****<https://cwiki.apache.org/**confluence/display/CLOUDSTACK/**>
>>>>>>> VM+Disk+IO+Throttling<https://**cwiki.apache.org/confluence/**
>>>>>>> display/CLOUDSTACK/VM+Disk+IO+**Throttling<https://cwiki.apache.org/confluence/display/CLOUDSTACK/VM+Disk+IO+Throttling>
>>>>>>>>
>>>>>>> [2] refs/heads/disk_io_throttling
>>>>>>> [3] https://issues.apache.org/****jira/browse/CLOUDSTACK-1301<https://issues.apache.org/**jira/browse/CLOUDSTACK-1301>
>>>>>>> <ht**tps://issues.apache.org/jira/**browse/CLOUDSTACK-1301<https://issues.apache.org/jira/browse/CLOUDSTACK-1301>
>>>>>>>>
>>>>>>> <ht**tps://issues.apache.org/**jira/**browse/CLOUDSTACK-2071<http://issues.apache.org/jira/**browse/CLOUDSTACK-2071>
>>>>>>> <**https://issues.apache.org/**jira/browse/CLOUDSTACK-2071<https://issues.apache.org/jira/browse/CLOUDSTACK-2071>
>>>>>>>>
>>>>>>>
>>>>>>>> (**CLOUDSTACK-1301
>>>>>>>>
>>>>>>>
>>>>>>> -     VM Disk I/O Throttling)
>>>>>>>
>>>>>>>
>>>>>>>
>>>>>>
>>>>>
>>>>
>>>
>>
>

Mime