axis-java-user mailing list archives

Site index · List index
Message view « Date » · « Thread »
Top « Date » · « Thread »
From "Adam.Leggett" <Adam.Legg...@upco.co.uk>
Subject RE: Axis/BEA WL 6.1 still issue...
Date Fri, 01 Mar 2002 09:45:24 GMT
Using Weblogic 6.1 SP2 and Axis alpha 3 we have solved this in a slightly
different way.

We used our own custom ConfigurationProvider implementation which looks for
a System property to specify a resource name,
so we can load our config from within the war in weblogic (Maybe the latest
build gives you this). Then we extended AxisServlet and provided our own
implementation of getEngine() to put this into the enviroment Map.

We are taking the approach that we do not need to write out to our wsdd
while the engine is up, ie dynamic deployment.

As I said, the nightly build may already provide for all this, but we are
sticking with alpha3 for now.

Cheers

Adam

-----Original Message-----
From: Glyn Normington [mailto:glyn_normington@uk.ibm.com] 
Sent: Friday, March 01, 2002 9:03 AM
To: axis-user@xml.apache.org
Subject: Re: Axis/BEA WL 6.1 still issue...



>I added "-Daxis.ServerConfigFile=E:\temp\server-config.wsdd" to the BEA
startup command line.

I wonder if file access is somehow restricted to the /WEB-INF directory? I'd
guess others are not using -Daxis.ServerConfigFile as it's relatively new
(and undocumented).

Glyn

Mime