aurora-dev mailing list archives

Site index · List index
Message view « Date » · « Thread »
Top « Date » · « Thread »
From "Bill Farner (JIRA)" <j...@apache.org>
Subject [jira] [Created] (AURORA-91) Thermos observer process timings are confusing for processes that have restarted
Date Thu, 23 Jan 2014 23:42:37 GMT
Bill Farner created AURORA-91:
---------------------------------

             Summary: Thermos observer process timings are confusing for processes that have
restarted
                 Key: AURORA-91
                 URL: https://issues.apache.org/jira/browse/AURORA-91
             Project: Aurora
          Issue Type: Task
          Components: Observer
            Reporter: Bill Farner
            Priority: Minor


Example:

{noformat}
name	 run	 status	 started	 finished	 cpu	 ram
fetch	 0	 SUCCESS	 12/03 07:39:54	 12/03 07:39:57
unzip	 0	 SUCCESS	 12/03 07:39:57	 12/03 07:39:57
run_server	 1	 FAILED	 12/03 08:44:03	 12/03 08:44:08
{noformat}

At a glance, it looks like 'run_server' didn't start for an hour after unzip finished.  As
it turns out, gimlet ran twice, and the first started right away.  Drilling into 'run_server'
reveals:

{noformat}
run	 status	 started	 finished
1	 FAILED	 12/03 08:44:03	 12/03 08:44:08
0	 SUCCESS	 12/03 07:39:58	 12/03 08:43:58
{noformat}

It might be more natural for the top-level page to report the start time of the first process,
and the finish time of the last process.



--
This message was sent by Atlassian JIRA
(v6.1.5#6160)

Mime