Hi Tim,

thanks for clarifying this. I may have expressed it not precisely in my
answer: the problem exactly was that for the broker1_broker2_simplex bridge,
when sending messages to a queue which is initially only known by broker 2
(because only there a consumer exists for this queue), sometimes doesn't go
1 -> 2, but goes 1 -> 3. Which is clear, since for a static bridge, broker 1
doesn't know which broker has the consumer, and since the includes conatin a
wildcard, it will just use round robin to send the messages to the connected
brokers.

So it's not about the duplex=false, but it's about the static bridge. When
using dynamic bridges as proposed, everything works fine.

Regards,
Jochen



--