Hello,

For the current 5.6 snapshot, I wrote a test which sends a frame after 
the time-out of the heart-beat elapsed.

Expected behaviour is that the broker does not accept any more data from 
the socket connection.

However the client can successfully send one message to the broker.

Because the client does not see an error, he assumes that the message is 
transmitted successfully.

The next (second) message sent will be rejected by the broker.

Maybe this test case could be added to the Stomp11Tests code?


send:
CONNECT
accept-version:1.1
server:localhost
heart-beat:1000,0



received:
CONNECTED
heart-beat:0,2000
session:ID:mj-PC-49595-1314256305896-2:24
server:ActiveMQ/5.6-SNAPSHOT
version:1.1


-- wait for five seconds --

send:
SEND
destination:/queue/TOOL.DEFAULT



send:
DISCONNECT

Thanks and regards
-- 
Michael Justin
habarisoft - Enterprise Messaging Software for Delphi