SIBBusModule-TestDeCharge-td0sib01v  Log
Link 1 : ADMIN Link port 61601 : Try to connect (DUPLEX initiator) from
SIBBusModule TestDeCharge (Client) to SIBBusSupervisor port 61601
2010-07-19 09:57:18,896 [arge-td0sib01v]] INFO  DiscoveryNetworkConnector     
- Establishing network connection from
vm://SIBBusModule-TestDeCharge-td0sib01v to
tcp://td0sib01s.priv.atos.fr:61601?useLocalHost=false

Link 1 : ADMIN Link port 61601 : Connect (DUPLEX initiator)  from
SIBBusModule TestDeCharge (Client) to SIBBusSupervisor port 61601
2010-07-19 09:57:19,068 [rge-td0sib01v#4] INFO  DemandForwardingBridge        
- Network connection between vm://SIBBusModule-TestDeCharge-td0sib01v#4 and
tcp://td0sib01s.priv.atos.fr/10.21.195.130:61601(SIBBusSupervisor-td0sib01s)
has been established.


STOP : Network Fault : Network Off

Link 1 : ADMIN Link port 61601 : (DUPLEX initiator) Link from SIBBusModule
TestDeCharge(Client) to SIBBusSupervisor port 61601, broken
2010-07-19 14:00:23,258 [arge-td0sib01v]] INFO  DemandForwardingBridge        
- SIBBusModule-TestDeCharge-td0sib01v bridge to SIBBusSupervisor-td0sib01s
stopped

Reconnect Processus : Network On

Link 1 new : ADMIN Link port 61601 : Try to connect (DUPLEX initiator)
SIBBusModule TestDeCharge(Client) to SIBBusSupervisor port 61601
2010-07-19 14:00:55,737 [arge-td0sib01v]] INFO  DiscoveryNetworkConnector     
- Establishing network connection from
vm://SIBBusModule-TestDeCharge-td0sib01v to
tcp://td0sib01s.priv.atos.fr:61601?useLocalHost=false

Link 1 new : ADMIN Link port 61601 : Connect (DUPLEX initiator)SIBBusModule
TestDeCharge(Client) to SIBBusSupervisor port 61601
2010-07-19 14:00:55,857 [ge-td0sib01v#11] INFO  DemandForwardingBridge        
- Network connection between vm://SIBBusModule-TestDeCharge-td0sib01v#11 and
tcp://td0sib01s.priv.atos.fr/10.21.195.130:61601(SIBBusSupervisor-td0sib01s)
has been established.


Link 1 doesn’t seem to work. 

SIBBusSupervisor log

Link 1 : ADMIN Link port 61601 : Connect (DUPLEX back) from SIBBusModule
TestDeCharge (Client) port 36485 to SIBBusSupervisor port 61601
2010-07-19 09:57:19,097 [0.29.12.1:36485] INFO  TransportConnection           
- Created Duplex Bridge back to SIBBusModule-TestDeCharge-td0sib01v
2010-07-19 09:57:19,097 [or-td0sib01s#12] INFO  DemandForwardingBridge        
- Network connection between vm://SIBBusSupervisor-td0sib01s#12 and
tcp:///10.29.12.1:36485(SIBBusModule-TestDeCharge-td0sib01v) has been
established.

STOP : Network Fault : Network Off

Link 1 : ADMIN Link port 61601 : (DUPLEX back) Link from SIBBusModule
TestDeCharge(Client) to SIBBusSupervisor port 61601, broken
2010-07-19 14:00:23,733 [isor-td0sib01s]] INFO  DemandForwardingBridge        
- SIBBusSupervisor-td0sib01s bridge to SIBBusModule-TestDeCharge-td0sib01v
stopped


Reconnect Processus : Network On

Link 1 new : ADMIN Link port 61601 : Connect (DUPLEX back) from SIBBusModule
TestDeCharge (Client) port 33840 to SIBBusSupervisor port 61601
2010-07-19 14:00:55,920 [0.29.12.1:33840] INFO  TransportConnection           
- Created Duplex Bridge back to SIBBusModule-TestDeCharge-td0sib01v
2010-07-19 14:00:55,921 [or-td0sib01s#22] INFO  DemandForwardingBridge        
- Network connection between vm://SIBBusSupervisor-td0sib01s#22 and
tcp:///10.29.12.1:33840(SIBBusModule-TestDeCharge-td0sib01v) has been
established.

STOP Old DUPLEX back Connection

Link 1 old : ADMIN Link port 61601 : (DUPLEX back) Link SIBBusModule
TestDeCharge (Client) port 36485 to SIBBusSupervisor port 61601 is broken
2010-07-19 14:00:58,939 [Worker@1ecc696e] WARN  DemandForwardingBridge        
- Network connection between vm://SIBBusSupervisor-td0sib01s#12 and
tcp:///10.29.12.1:36485 shutdown due to a remote error:
org.apache.activemq.transport.InactivityIOException: Channel was inactive
for too long: /10.29.12.1:36485
2010-07-19 14:00:58,945 [0.29.12.1:36485] INFO  DemandForwardingBridge        
- SIBBusSupervisor-td0sib01s bridge to SIBBusModule-TestDeCharge-td0sib01v
stopped


It seems that bridge on Link 1 is finally broken ???

Eric-AWL


Eric-AWL wrote:
> 
> Hi
> 
> In the case where network is alternatively on/off in a duplex multicast
> configuration, I first discovered that the "network connector side" broker
> was sometimes blocked on "RemoteBrokerNameKnownLatch" latch.
> 
> I think that I resolved this problem by 
> - adding a countdown() call on this latch at the end of the stop() method
> - correctly managing an exception to alert the discovery connector that
> the bridge was disposed during the start call.
> 
> Now, I think that I have a problem on the other side with this
> configuration.
> T0                                   - A duplex connection is correctly
> established
> T0+X minutes                    - the network is down, the duplex bridge
> back is stopped, but the corresponding transport (back) connection seems
> not to be closed
> T0+X minutes + x ms          - the networl is up : a new transport
> connection want to be established and is established
> T0+X minutes + y seconds   - the transport inactivity thread closes the
> old transport connection
> 
> (y seconds >> x milliseconds)
> 
> All seems Ok, but no message are exchanged with this bridge.
> 
> Eric-AWL
> 

-- 
View this message in context: http://old.nabble.com/Duplex-and-network-fault.-tp29205793p29212515.html
Sent from the ActiveMQ - User mailing list archive at Nabble.com.


Mime
View raw message