This problem is not appearing in the latest snapshot (2008-09-29).

Another issue surfaced though; when restarting the broker the journal is
still locked. Isn't the broker.stop() suppose to unlock the journal if it's
the only (or last) broker running?




taf wrote:
> 
> Hi,
> I'm running activemq embedded and wants to be able to restart the broker
> without terminating the host application. The broker starts fine on
> application startup and calling stop() therafter also works fine, but when
> trying to start it again, it results in a BrokerStoppedException.
> 
> I've traced the call into the start method in MutableBrokerFilter where
> the call to getNext().start() actually returns an ErrorBroker (which
> of-course gives me a BrokerStoppedException when trying to start it).
> 
> I would have thought that the call should be this.start(), as my broker is
> successfully bound to this.
> And why does getNext even return an ErrorBroker?
> 
> Am I missing something obvious here?
> 
> Regards,
> - Torgeir Fikse
> 
> 
> 

-- 
View this message in context: http://www.nabble.com/Restart-of-embedded-broker-causes-BrokerStoppedException-tp19198844p19737754.html