Hello,

I have one central broker on a central host named neurath; here the central broker configuration:

 
<beans>
	<bean class="org.springframework.beans.factory.config.PropertyPlaceholderConfigurer"/>
	<broker useJmx="false" xmlns="http://activemq.org/config/1.0" persistent="false">
		<transportConnectors>
			<transportConnector name="default" uri="tcp://neurath.gaia-group.local:61616" discoveryUri="multicast://default"/>
			<transportConnector name="stomp" uri="stomp://neurath.gaia-group.local:61613"/>
		</transportConnectors>
		<networkConnectors>
			<networkConnector name="default" uri="multicast://default" bridgeTempDestinations="true"
conduitSubscriptions="false" dynamicOnly="false" />
		</networkConnectors>
	</broker>
</beans>
 

A second broker is running on a second machine named london and connects to the central broker:

<beans>
	<bean class="org.springframework.beans.factory.config.PropertyPlaceholderConfigurer"/>
	<broker useJmx="false" xmlns="http://activemq.org/config/1.0" persistent="false">
		<transportConnectors>
			<transportConnector name="default" uri="tcp://london.gaia-group.local:61616" discoveryUri="multicast://default"/>
			<transportConnector name="stomp" uri="stomp://london.gaia-group.local:61613"/>
		</transportConnectors>
		<networkConnectors>
			<networkConnector name="default" uri="static://(tcp://neurath.gaia-group.local:61616)"
bridgeTempDestinations="true" conduitSubscriptions="false" dynamicOnly="false" />
		</networkConnectors>
	</broker>
</beans>


Now I have a Lingo server connected to the central broker. The Lingo client is connect to
the second broker on the second machine. 

With this setup I run into the attached execption on the Lingo server side. Who can help me
here?

Thx,

Bernhard



_____________________________________________
|
| GAIA AG 
| Dr. Bernhard Wellhöfer
| Holstenwall 7
| 20355 Hamburg
| Germany 
| Voice: ++49.40.351052-25 
| Fax: ++49.40.351052-10
| mailto:Bernhard.Wellhoefer@gaia-group.com <mailto:Bernhard.Wellhoefer@gaia-group.com>

| www.gaia-group.com <http://www.gaia-group.com/> 
|_____________________________________________


Mime
View raw message