What's the use-case for needing to "align" <slow-consumer-threshold> and <slow-consumer-check-period>?


Justin

----- Original Message -----
From: "Jiri Danek" <jdanek@redhat.com>
To: dev@activemq.apache.org
Sent: Friday, February 10, 2017 3:26:01 PM
Subject: Re: [DISCUSS] ActiveMQ Artemis 2.x stream

On Thu, Feb 9, 2017 at 1:18 PM, Martyn Taylor <mtaylor@redhat.com> wrote:

> I'd like to open discussion around this topic, does anyone have any
> suggestions, or can think of anything that is needed before we go ahead
> with a major release? This is the perfect time to do anything that could
> break APIs, drop deprecated methods support, break data format etc...
>

What about changing units on config option

<slow-consumer-threshold>100</slow-consumer-threshold>

currently it is in messages/second, I suggest using messages/minute, to
align it with

<slow-consumer-check-period>5</slow-consumer-check-period>

which is in minutes.

-- 