Robert Balent created AMQ-4258:
----------------------------------

             Summary: Endless loop when received incorrect AMQP message
                 Key: AMQ-4258
                 URL: https://issues.apache.org/jira/browse/AMQ-4258
             Project: ActiveMQ
          Issue Type: Bug
          Components: Transport
    Affects Versions: 5.8.0
            Reporter: Robert Balent
            Priority: Critical
         Attachments: patch1.txt

When you send incorrect message to AMQP transform, it will stuck in endless loop and write
lot of error messages to console output.

This way, you can send numbers of incorrect messages and ActiveMQ will create new thread for
each of them. This way can attacker create thousands of threads in few minutes and completely
overload server machine.

Problem is in org.apache.activemq.transport.amqp.AmqpProtocolConverter class. It throws exception(exception.txt)
and loop never ends:

Line 158:
int count = protonTransport.input(frame.data, frame.offset, frame.length);

Two solutions are possible:

1. Add "return" statement to catch block (patch1.txt).
2. Run "frame.moveHead(count);" in finally block with some default positive count (patch2.txt)

I would prefer the first variant.

This happens when you try to send message from client with older version of AMQP protocol.

--
This message is automatically generated by JIRA.