Subject [jira] Created: (AMQ-2133) activemq-flow's dispatcher's TimerHeap is converting units backwards
Date Fri, 20 Feb 2009 22:00:02 GMT
activemq-flow's dispatcher's TimerHeap is converting units backwards
--------------------------------------------------------------------

                 Key: AMQ-2133
                 URL: https://issues.apache.org/activemq/browse/AMQ-2133
             Project: ActiveMQ
          Issue Type: Bug
    Affects Versions: incubation
            Reporter: Colin MacNaughton
             Fix For: incubation


When a timer is added to the heap the units were being converted backwards so that adding
a Runnable that is suppose to execute in 5000ms would execute in 5 nanoseconds.

-- 