ying commented on AMQ-1832:
---------------------------

to AMQ-1825, I am not sure this patch will solve your problems. i haven't run into those.

As to my patch, if you don' t use the shutdownOnSlaveFailure, everything will work the same
as without the patch. 

Stopping one master is ok when you configure a network of pair of master/slave (eg, 3 pairs)
and have redelivery policy set up properly so when some error happens on one pair, all the
messages will be sent to another pair of master/slave. The way we want to have this is to
make sure master and slave are in sync.

> Pure Master/Slave to allow shutdownOnSlaveFailure to be configured on master
> ----------------------------------------------------------------------------
>
>                 Key: AMQ-1832
>                 URL: https://issues.apache.org/activemq/browse/AMQ-1832
>             Project: ActiveMQ
>          Issue Type: Improvement
>            Reporter: ying
>         Attachments: AMQ1832-596-1820Patch.txt
>
>
> It is related to AMQ-596 in terms that it is desirable that master and slave are in synch
and when both are down, failover can direct the job to other pair of master/slave. So pure
master/slave can be used for replication while a network of pair (master/slave) will provide
a HA service. 

-- 