ying commented on AMQ-1813:
---------------------------

using tcp://master:61616 for masterConnectorURI and shutdownOnMasterFailure="true" , I got
the same result.  I think this needs to be fixed too.

but using failover://(tcp://master:61616)?maxReconnectAttempts=3 as the masterConnectorURI
, after 3 failed attemp, it will shut down the slave. so shutdownOnMasterFailure is not ignored
in the failover protocol case.

> shutdownOnMasterFailure="true" is ignored when broker starting
> --------------------------------------------------------------
>
>                 Key: AMQ-1813
>                 URL: https://issues.apache.org/activemq/browse/AMQ-1813
>             Project: ActiveMQ
>          Issue Type: Bug
>          Components: Broker
>    Affects Versions: 5.1.0
>            Reporter: Dima
>
> If slave broker cannot connect to master when slave broker starting, slave broker doesn't
stop starting and starts all connectors
> I think it's a bad behavior. It must shutdown when shutdownOnMasterFailure="true" 

-- 
This message is automatically generated by JIRA.
-