Kieran Murphy closed AMQ-630.
-----------------------------

    Resolution: Fixed

This is fixed, but the client using the failover protocol must  be configured with the maxReconnectAttempts
argument set.  If maxReconnectAttempts is not set, then the client tries forever to reconnect
and this seems to block the client's shutdown.  As long as maxReconnectAttempts value is non-zero,
then the client will be able to shutdown when no brokers are online.

> After broker has shutdown, cannot shutdown a client application
> ---------------------------------------------------------------
>
>                 Key: AMQ-630
>                 URL: https://issues.apache.org/activemq/browse/AMQ-630
>             Project: ActiveMQ
>          Issue Type: Bug
>    Affects Versions: 4.0 M4
>            Reporter: Kieran Murphy
>         Assigned To: Hiram Chirino
>             Fix For: 4.1
>
>
> 1.  Bring up a broker
> 2.  Bring up a client application which connects to the broker
> 3.  Stop the broker.
> 4.  Now try to stop the client app -- it will not shutdown until the broker is restarted.
 
> Using failover:tcp to connect to broker.

-- 