Chris Berry wrote:
> BTW: Note: time is definitely not accurate enough here for paging.  
> Several items may get the same time-stamp (due to DB Date 
> accuracy, multi-threading, multi-servers, ...)

Instead of assigning each entry a unique, monotonically-increasing
serial number, I assign each entry a unique, monotonically-increasing
timestamp (app:edited). This enables me to page using the timestamps
without issue.

- Brian